中文

LightNing® SbfI

REF No.:
  • EG15568S
Specs:
25 rxns (500 U)
Price:
$42
Isoschizomers:
SdaI, Sse8387I
Cut site:
CCTGCAGG

5'...C C T G C A ↓ G G...3'
3'...G G ↑ A C G T C C...5'

Description

       LightNing® enzymes are a series of engineered restriction enzymes that are capable of fast DNA digestion. All LightNing® enzymes show superior activity in the universal CutOne® and CutOne® Color Buffer, and are able to digest DNA in 5~15 minutes. This enables any combination of restriction enzymes to work simultaneously in one reaction tube and eliminates the need for sequential digestions. LightNing® enzymes have passed multiple strict quality controls, and can be used to digest plasmid, genomic and viral DNA as well as PCR products.
       CutOne® Color Buffer includes a density reagent along with red and yellow tracking dyes that allow for direct loading of the reaction mixtures on a gel. The red dye of the CutOne® Color Buffer migrates with 2.5 kb double-strand DNA fragments in a 1% agarose gel, and the yellow dye migrates with 10 bp double-strand DNA fragments in a 1% agarose gel.

Components

Component

Amount

LightNing® SbfI (20 U/μl)

25 μl (500 U)

10× CutOne® Buffer

1 ml

10× CutOne® Color Buffer

1 ml

Features and Usage

The reaction can be completed within 15 minutes

 

Recommended Reaction Conditions

1× CutOne® Buffer;
Incubate at 37℃;
Refer to "Protocol for Fast DNA Digestion" for reaction setup.

 

Heat Inactivation

Incubation at 80℃ for 20 minutes.

Storage Condition

-20℃

Download

FAQs

  • Q:

    How stable is a restriction enzyme during storage?

    A:

    Most restriction enzymes are stable through their shelf life when stored at -20°C in the supplied storage buffer. Keep exposure to temperatures above -20°C to a minimum, and use a cooling block while setting up reactions.

  • Q:

    How do I stop a restriction digest?

    A:

    Add stop solution (500 mM EDTA, pH 8.0, 5 µl per 50 µl reaction) if the DNA will not be used further. If it will, heat-inactivate at 80°C for 20 minutes — check the datasheet first, as this does not work for every enzyme. Phenol/chloroform extraction is an alternative.

  • Q:

    How can I find an enzyme by sequence, overhang or name?

    A:

    Use EnzymeFinder under Technical Information. It searches by enzyme name, recognition sequence, overhang type or enzyme class, and returns matching products with catalogue numbers.

  • Q:

    Do degenerate recognition sites need to be palindromic?

    A:

    No. Most sites are palindromic, but degenerate sites contain positions that accept more than one base. AccI (GTMKAC) cuts GTATAC, GTAGAC, GTCGAC and GTCTAC. Any base allowed by the single-letter code at either position permits cleavage.

  • Q:

    What happens if LightNing® enzymes freeze during shipment?

    A:

    EQuality is not affected. Every LightNing® enzyme is tested for full activity after at least three freeze-thaw cycles, and short exposure to 4°C during 24 to 48 hour delivery does not reduce performance.

  • Q:

    Why do I see unexpected bands after digestion?

    A:

    Check four causes in order: star activity (reduce enzyme, shorten incubation, increase volume), incomplete digestion (add enzyme or time, purify the DNA), contaminating nucleases from handling, and poor mixing. A no-enzyme control separates template damage from digestion problems.

  • Q:

    What promotes star activity?

    A:

    Star activity is promoted by prolonged incubation, excess enzyme, glycerol above 5% in the reaction, and small reaction volumes. Keep the reaction at 1× buffer, use the minimum enzyme volume required, and do not incubate beyond the validated time.

  • Q:

    Why did my digestion fail or stay incomplete?

    A:

    Most failures come from inhibitors in the template: phenol, chloroform, detergents, ethanol, excess salt or EDTA. Run three controls — DNA without enzyme, clean control DNA with enzyme, and clean plus test DNA together. Also check whether the site is blocked by Dam or CpG methylation.

  • Q:

    Can CutOne buffers be stored at 4°C?

    A:

    CutOne and CutOne Color buffers can be kept at 4°C for at least six months. For storage up to the stated expiry, keep them at -20°C.

  • Q:

    What is the difference between CutOne and CutOne Color buffer?

    A:

    Same performance, one difference: the Color version contains a density reagent and two tracking dyes, so the reaction can be loaded directly onto a gel. Red migrates with ~2.5 kb and yellow with ~10 bp fragments in a 1% agarose gel.

  • Q:

    How do I convert LightNing® enzyme units into reactions?

    A:

    One rxn is defined as 1 µl of enzyme cleaving 1 µg of substrate DNA in 15 minutes at the optimal temperature (usually 37°C) in 20 µl of 1× CutOne buffer. Enzyme concentration itself is proprietary; use this definition to convert between pack sizes.

  • Q:

    Do LightNing® enzymes contain BSA?

    A:

    No. We use recombinant human albumin (rHSA) instead of bovine BSA, so LightNing® enzymes contain no animal-derived components.

  • Q:

    How many bases are needed flanking the recognition site?

    A:

    Allow at least six base pairs upstream and downstream of the recognition site. There is no sequence requirement for these flanking bases.

  • Q:

    Can I digest longer than 15 minutes with LightNing® enzymes?

    A:

    Yes. LightNing® enzymes are qualified for extended digestion without DNA degradation, up to three hours. Five to fifteen minutes is the recommended working range for most templates.