PRODUCT
LightNing® SdaI (SbfI)
- EG24515S
5'...C C T G C A ↓ G G...3'
3'...G G ↑ A C G T C C...5'
Description
LightNing® enzymes are a series of engineered restriction enzymes that are capable of fast DNA digestion. All LightNing® enzymes show superior activity in the universal CutOne® and CutOne® Color Buffer, and are able to digest DNA in 5~15 minutes. This enables any combination of restriction enzymes to work simultaneously in one reaction tube and eliminates the need for sequential digestions. LightNing® enzymes have passed multiple strict quality controls, and can be used to digest plasmid, genomic and viral DNA as well as PCR products.
CutOne® Color Buffer includes a density reagent along with red and yellow tracking dyes that allow for direct loading of the reaction mixtures on a gel. The red dye of the CutOne® Color Buffer migrates with 2.5 kb double-strand DNA fragments in a 1% agarose gel, and the yellow dye migrates with 10 bp double-strand DNA fragments in a 1% agarose gel.
Components
|
Component |
Amount |
|
LightNing® SdaI (20 U/μl) |
25 μl (500 U) |
|
10× CutOne® Buffer |
1 ml |
|
10× CutOne® Color Buffer |
1 ml |
Features and Usage
The reaction can be completed within 15 minutes
Recommended Reaction Conditions
1× CutOne® Buffer;
Incubate at 37℃;
Refer to "Protocol for Fast DNA Digestion" for reaction setup.
Heat Inactivation
Incubation at 65℃ for 5 minutes.
Storage Condition
-20℃
Download
FAQs
-
Q:
How stable is a restriction enzyme during storage?
A:Most restriction enzymes are stable through their shelf life when stored at -20°C in the supplied storage buffer. Keep exposure to temperatures above -20°C to a minimum, and use a cooling block while setting up reactions.
-
Q:
How do I stop a restriction digest?
A:Add stop solution (500 mM EDTA, pH 8.0, 5 µl per 50 µl reaction) if the DNA will not be used further. If it will, heat-inactivate at 80°C for 20 minutes — check the datasheet first, as this does not work for every enzyme. Phenol/chloroform extraction is an alternative.
-
Q:
How can I find an enzyme by sequence, overhang or name?
A:Use EnzymeFinder under Technical Information. It searches by enzyme name, recognition sequence, overhang type or enzyme class, and returns matching products with catalogue numbers.
-
Q:
Do degenerate recognition sites need to be palindromic?
A:No. Most sites are palindromic, but degenerate sites contain positions that accept more than one base. AccI (GTMKAC) cuts GTATAC, GTAGAC, GTCGAC and GTCTAC. Any base allowed by the single-letter code at either position permits cleavage.
-
Q:
What happens if LightNing® enzymes freeze during shipment?
A:EQuality is not affected. Every LightNing® enzyme is tested for full activity after at least three freeze-thaw cycles, and short exposure to 4°C during 24 to 48 hour delivery does not reduce performance.
-
Q:
Why do I see unexpected bands after digestion?
A:Check four causes in order: star activity (reduce enzyme, shorten incubation, increase volume), incomplete digestion (add enzyme or time, purify the DNA), contaminating nucleases from handling, and poor mixing. A no-enzyme control separates template damage from digestion problems.
-
Q:
What promotes star activity?
A:Star activity is promoted by prolonged incubation, excess enzyme, glycerol above 5% in the reaction, and small reaction volumes. Keep the reaction at 1× buffer, use the minimum enzyme volume required, and do not incubate beyond the validated time.
-
Q:
Why did my digestion fail or stay incomplete?
A:Most failures come from inhibitors in the template: phenol, chloroform, detergents, ethanol, excess salt or EDTA. Run three controls — DNA without enzyme, clean control DNA with enzyme, and clean plus test DNA together. Also check whether the site is blocked by Dam or CpG methylation.
-
Q:
Can CutOne buffers be stored at 4°C?
A:CutOne and CutOne Color buffers can be kept at 4°C for at least six months. For storage up to the stated expiry, keep them at -20°C.
-
Q:
What is the difference between CutOne and CutOne Color buffer?
A:Same performance, one difference: the Color version contains a density reagent and two tracking dyes, so the reaction can be loaded directly onto a gel. Red migrates with ~2.5 kb and yellow with ~10 bp fragments in a 1% agarose gel.
-
Q:
How do I convert LightNing® enzyme units into reactions?
A:One rxn is defined as 1 µl of enzyme cleaving 1 µg of substrate DNA in 15 minutes at the optimal temperature (usually 37°C) in 20 µl of 1× CutOne buffer. Enzyme concentration itself is proprietary; use this definition to convert between pack sizes.
-
Q:
Do LightNing® enzymes contain BSA?
A:No. We use recombinant human albumin (rHSA) instead of bovine BSA, so LightNing® enzymes contain no animal-derived components.
-
Q:
How many bases are needed flanking the recognition site?
A:Allow at least six base pairs upstream and downstream of the recognition site. There is no sequence requirement for these flanking bases.
-
Q:
Can I digest longer than 15 minutes with LightNing® enzymes?
A:Yes. LightNing® enzymes are qualified for extended digestion without DNA degradation, up to three hours. Five to fifteen minutes is the recommended working range for most templates.